Architecture
Quiz Portal
« All Events
/5 1 GATE Architecture & Govt. Jobs Prepare for GATE Architecture & Planning (AR) 2027-28 with free online quizzes and mock tests by KP GATE Classes. Practice Architecture MCQs, PYQs, Planning, Structures, Building Materials, and Government Architecture Exam questions with instant answers and real exam-level practice. Coefficient of Performance (COP) for heat pump is used to calculate: the Energy Efficiency Ratio the Energy Select Sector index the number of air changes the Indoor Air Quality index Both Energy Efficiency Ratio (EER) and Coefficient of Performance (COP) indicate the ratio of heating or cooling provided by a unit relative to the amount of electrical input required to generate it. Thus, if an air conditioner generates 5kW of heat from a 1kW electrical input, its COP is said to be 5.0. The higher the COP and EER, the more energy efficient is the equipment. Rebound hammer test is used to measure: permeability of concrete compressive strength of concrete bond stress between rebar and concrete tensile strength of concrete Rebound hammer test is done to find out the compressive strength of concrete by using rebound hammer as per IS: 13311 (Part 2) - 1992. The underlying principle of the rebound hammer test is: The rebound in the hammer is a function of the surface hardness and therefore the rebound is taken to be related to the compressive strength of the concrete. An urban governance tool to mobilize financial resources by permitting additional FAR over and above the prescribed FAR by imposing a charge or fee for the same is known as: Impact Fee Land Value Increment Tax Betterment Levy Floor Area Incentive Tax Land value increment tax or betterment tax is an old land based fiscal tool that was introduced in the legislation related to city improvement trusts in the last decade of the nineteenth century. Later the concept was incorporated in the town planning schemes. Provisions also exist to capture land value increments in case of specific projects. (Source: Land Based Fiscal Tools and Practices for Generating Additional Financial Resources, August 2013; supported under Capacity Building for Urban Development project (CBUD), a partnership program between Ministry of Urban Development, Government of India & The World Bank) Freight flows are converted to truck flows using: Weight factor Volume factor Distance load factor Payload factor Transportation agencies analyze highway deficiencies based on the number of vehicles traveling on highway facilities and comparing that demand to the capacity of those facilities. Freight Analysis Framework reports forecasts annual flows in tons between origins and destinations. In truck based models: Truck surveys are used for estimating choice parameter. Freight flows are converted into truck flows using payload factor. Payload factors are determined from truck surveys and weigh bridge data. (Average amount of load in different kind of vehicles can be determined by survey or weigh bridge) Identify the colour palette that is created using any three equally spaced hues around the colour wheel. Analogous Complementary Triads Split – complementary A triadic colour scheme is comprised of three colours evenly spaced on the colour wheel. The two most basic triadic palettes are the primary colours red, blue, and yellow and the secondary hues orange, purple, and green. Congratulations! You’ve completed the test. Fill out the form to view your result. Your score isThe average score is 40% 0% Restart quiz
GATE Architecture & Govt. Jobs
Prepare for GATE Architecture & Planning (AR) 2027-28 with free online quizzes and mock tests by KP GATE Classes. Practice Architecture MCQs, PYQs, Planning, Structures, Building Materials, and Government Architecture Exam questions with instant answers and real exam-level practice.
Coefficient of Performance (COP) for heat pump is used to calculate:
Both Energy Efficiency Ratio (EER) and Coefficient of Performance (COP) indicate the ratio of heating or cooling provided by a unit relative to the amount of electrical input required to generate it. Thus, if an air conditioner generates 5kW of heat from a 1kW electrical input, its COP is said to be 5.0. The higher the COP and EER, the more energy efficient is the equipment.
Rebound hammer test is used to measure:
Rebound hammer test is done to find out the compressive strength of concrete by using rebound hammer as per IS: 13311 (Part 2) - 1992. The underlying principle of the rebound hammer test is: The rebound in the hammer is a function of the surface hardness and therefore the rebound is taken to be related to the compressive strength of the concrete.
An urban governance tool to mobilize financial resources by permitting additional FAR over and above the prescribed FAR by imposing a charge or fee for the same is known as:
Land value increment tax or betterment tax is an old land based fiscal tool that was introduced in the legislation related to city improvement trusts in the last decade of the nineteenth century. Later the concept was incorporated in the town planning schemes. Provisions also exist to capture land value increments in case of specific projects. (Source: Land Based Fiscal Tools and Practices for Generating Additional Financial Resources, August 2013; supported under Capacity Building for Urban Development project (CBUD), a partnership program between Ministry of Urban Development, Government of India & The World Bank)
Freight flows are converted to truck flows using:
Transportation agencies analyze highway deficiencies based on the number of vehicles traveling on highway facilities and comparing that demand to the capacity of those facilities. Freight Analysis Framework reports forecasts annual flows in tons between origins and destinations. In truck based models: Truck surveys are used for estimating choice parameter. Freight flows are converted into truck flows using payload factor. Payload factors are determined from truck surveys and weigh bridge data. (Average amount of load in different kind of vehicles can be determined by survey or weigh bridge)
Identify the colour palette that is created using any three equally spaced hues around the colour wheel.
A triadic colour scheme is comprised of three colours evenly spaced on the colour wheel. The two most basic triadic palettes are the primary colours red, blue, and yellow and the secondary hues orange, purple, and green.
Congratulations! You’ve completed the test. Fill out the form to view your result.
Your score is
The average score is 40%
Restart quiz